Showing posts with label Range hood noise. Show all posts
Showing posts with label Range hood noise. Show all posts

Monday, February 27, 2012

Optimal use of remote range hood blowers

There are three basic forms of range hoods blowers:
  • Internal range hood blower - the range hood blower is located inside of the range hood canopy
  • Inline to the duct run - the range hood blower is located somewhere along the range hood exhaust ducting
  • External to the range hood - the range hood blower is located either on the roof or on an external wall

Internal range hood blower


External range hood blower

Inline range hood blower
If the cooking equipment - the stove or the range dicatate (based on the btu to cfm calculation that can be found on posts in this blog) that around 600cfm is required then there is not a great deal of benefit to be achieved by placing the range hood blower remote from the range hood canopy

Noise is one of the main reasons why remote blowers for range hoods are installed. If the range hood blower, whether inline or external is close to the range hood very little benefit in term so of noise reduction will be achieved.

An external blower mounted on the wall directly behind the range hood without any bends in the duct run will not help the noise a great deal.

For optimal noise reduction from an external blower there should be at least one 90 degree bend in the duct run.

For optinal noise reduction a duct silencer system can be placed in the duct run.

Duct silencers

Saturday, February 4, 2012

Range hood Noise and how to manage it

The critical factors in noise reduction are:

-          Type of filters
-          Quality of duct work – appropriate size for the airflow, length and number of bends
-          Quality and size of blower used

Filters:

There are in essence two types of filters – mesh and baffle. Baffle filters are quieter, 96% efficient and excellent fire travel blockers. Mesh are only recommended in lower cfm applications around 400cfm to 600cfm and over electric style cook tops.

Quality of ductwork:

The most critical element is the size and quality of duct material relative to the maximum airflow you try to move down that duct – for 400cfm internal blowers we recommend 7”, for 600cfm internal blowers 8” and 1200cfm internal blowers 10”. Inline blowers between 600 and 1000cfm need 8” duct and external blowers of 1000cfm 8” duct. Rigid metal duct is strongly recommended – flexible ribbed ducting will be noisy because the air is “tripping” of the ridges and makes noise.

The average duct length and number of bends found today is not too much of an issue – if bends and length is excessive then external blowers and more powerful blowers should be used – if a blowers is trying to “PUSH” a high volume of air down a long and wavy duct run the motor needs to work harder and of course will be noisier.

Blowers:

These  come in all forms of quality – the quality blowers have less mechanical noise because they are well made and balanced.


An internal range hood blower

An external range hood blower
roof or wall mount
An inline range hood blower